What is flood light?
The floodlight is a point light source that can illuminate evenly in all directions. Its illumination range can be adjusted arbitrarily, and it appears as a regular octahedron icon in the scene. Floodlights are the most widely used light source in the production of renderings. Standard floodlights are used to illuminate the entire scene. Multiple floodlights can be used in the scene. In order to produce better lighting effects. The light bulb for shooting is installed in a large reflecting umbrella for use as a high-brightness diffused light source. Although it is indispensable for lighting in the studio, it can also be regarded as one of the light sources with good lighting effects for ordinary amateur indoor photography.
What is the Advantages of LED Flood Light?
Features of LED flood light
What is LED flood light? It is mainly used for public lighting, sports lighting, architectural decoration lighting, municipal lighting, and commercial space lighting. It also has a certain decorative composition. Its appearance is round or square, because heat dissipation generally has to be considered, so its appearance is still somewhat different from traditional floodlights.
LED floodlights are actually composed of LED light source, reflector cup, radiator and driving power supply. They have some characteristics of their own:
- High-purity aluminum reflector, the most accurate beam, the best reflection effect,
- Symmetrical narrow-angle, wide-angle and asymmetric light distribution systems,
- Open the back to replace the bulb, easy to maintain,
- The lamps are all attached with a scale plate to facilitate the adjustment of the irradiation angle.
The LED flood light is controlled by a built-in microchip. In small engineering applications, it can be used without a controller. It can achieve dynamic effects such as gradation, jump, color flashing, random flashing, and gradual alternation. It can also be controlled by DMX. Achieve effects such as chasing and scanning.
What is the Best LED Flood Light?
As a replacement product of traditional high-pressure sodium light sources, LED floodlights have been recognized by more and more people and have been applied in many fields.
As the world’s leading lighting industry leader, high-power LED floodlight has been widely used in stadiums,
mining areas, petrochemical plants, municipal public places, highways and tunnels, etc., to maximize the lighting needs of various places. At the same time, light pollution is avoided.
Tachyon LED flood light has the following advantages:
- Long lifespan: General incandescent lamps, fluorescent lamps, energy-saving lamps, and other gas discharge lamps have filaments or electrodes, and the sputtering effect of filaments or electrodes is an inevitable component that limits the life of the lamp. The LED lamp requires no or less maintenance, has high reliability, and has a service life of up to 80,000 hours (calculated by 10 hours per day, the life can reach more than 10 years). Compared with other lamps, it is 60 times longer than incandescent lamps, 12 times longer than energy-saving lamps, 12 times longer than fluorescent lamps, and 20 times longer than high-pressure mercury lamps. The long life of LED floodlights greatly reduces maintenance troubles and replacement times, saves material costs and labor costs, and can ensure long-term normal use. The service life is only determined by the quality level of electronic components, circuit design and foam manufacturing process, and the service life can generally reach 60,000 to 100,000 hours.
- Energy saving: Compared with incandescent lamp, energy saving is about 75%. The luminous flux of 85W LED flood light is roughly equivalent to that of 500W incandescent lamp.
- Environmental protection: Tachyon LED floodlight does not contain mercury, fluorescent agents and metal halides. Even if it is broken, it will not pollute the environment. With a recyclability rate of over 99%, it is a truly environmentally friendly green light source.
- No stroboscopic: Because of its high working frequency, it is regarded as “no stroboscopic effect”, will not cause eye fatigue and protect eye health.
- Good color rendering: the color rendering index is greater than 80, the light color is soft, showing the natural color of the illuminated object.
- The color temperature is optional: from 2700K to 6500K, it can be selected by customers according to their needs, and can be made into RGB floodlight for garden decoration lighting and municipal lighting projects.
- High proportion of visible light: In the emitted light, the proportion of visible light is more than 80%, and the
visual effect is good. - No preheating is required. It can be started and restarted immediately, and the light decay phenomenon in ordinary discharge lamps with electrodes will not occur after multiple switching.
- Excellent electrical performance: power factor is as high as 0.98, current harmonics are low, constant voltage power supply, constant luminous flux output.
- Installation adaptability: It can be installed in any position without restriction.
Application of Tachyon LED flood light
- Football Stadium
Guide to artificial lighting of football fields: FIFA. This standard includes content such as competition classification, lighting requirements, recommended values of lighting parameters, and field lighting measurement. It is currently the most comprehensive and up-to-date standard for artificial lighting in football fields. This standard was applied in the 2002 World Cup in Korea and Japan.
Football lighting is divided into football field lighting and off-field football field lighting, the installation of lights is different in different venues. The standard should be based on the function of the football field to determine the lighting standard, roughly divided into seven levels, training and entertainment activities illuminance 200lx, amateur games 500lx, professional games 750lx, general TV broadcast 1000lx, large-scale international game HD TV broadcast 1400lx, TV emergency 750lx.
- Cricket Field
Lighting technical requirements for the competition venue:
Horizontal illuminance 1500lx, vertical illuminance 1000lx, horizontal illuminance uniformity U1=0.5, U2=0.6, vertical illuminance uniformity U1=0.4, U2=0.5, light source color temperature 4000K~6500K, color rendering index Ra>85, auditorium horizontal illuminance 150lx , The horizontal illuminance of VIP seats is 300lx, and the vertical illuminance of VIP seats is 250lx.
- Horse Arena
The equestrian field planning is divided into five functional areas, which are: the track stables and related ancillary facilities, Logistics comprehensive area, baidu center field and training field area, audience square area and racetrack entrance area.
The center area includes a main stadium of 120 m x108 m, a warm-up field of 80m x60m, an 80 m X80 m dressage training field, which can be divided into three Olympic standard 60 m X20 m full-length dance steps field, an 80 m X60 meter obstacle training field to walk the horse track and cooling room. The equestrian events will be held in the center, and the off-road race will be conducted on the specially designed sand track with a length of about 2500 meters. There are 20 obstacles on the track.
The starting point and end of the track are all on the center field. The spectator stands are set up in the south, North and west of the center stadium, which can provide about 6000 seats for the audience, VIP and media to watch the competition at the same time.
- Futsal Court Football Stadium Lighting Standard:
Futsal Court length: 70 meters, width: 50 meters;The stadium lighting must be uniform, the luminosity must be sufficient, and the placement of lighting equipment must not prevent the players’ vision. According to the calculation of the on-site stadium, it is required to meet the standards of general entertainment activities and amateur training, and the average illuminance in the stadium is about 300lx.